Updated the RESTful API HPE BIOS Attribute Registry resources to match the latest BIOS/Platform Configuration options. Once the power supply is plugged in, the system health LED should have returned to the blinking GREEN state. This issue only impacts systems configured with Intel Xeon v4 Series processors. This issue would not be seen if the ROM Based Setup Utility (RBSU) Option for Dynamic Power Calibration is set to Disabled (the default for this option is Auto which could result in this issue). The number of active cores would not be reported properly by some utilities. Added support for a new restclient command in the Embedded UEFI Shell. Updated the HPRESTful API support to report and set the default UEFI Boot Order settings using the HpServerBootOrder resource type. At the end of a successful installation of the SoftPaq a web page will automatically appear to provide you with the different methods for restoring and/or upgrading the firmware on the system. Addressed an issue with some network devices name display in the System Utilities. Intel has only seen this under synthetic testing conditions and is not aware of any commercially available software exhibiting this behavior. No branding changes were made that could impact software running on the system. I have just installed Server 2012 R2 on my HP ProLiant DL380 G5. This issue did not affect servers configured for UEFI Boot Mode. Addressed an issue where the internal SD card would remain active after the user has disabled the SD slot from System Utilities BIOS/Platform Configuration (RBSU) option. This option can be selected from the Advanced Memory Protection Mode selection. For Proliant Gen8/9/10, HP has released a new firmware (ROM) to mitigate the impact of Meltdown and Spectre. Board HP ProLiant DL380 Gen9 . Support for OHCI USB controllers should be available from operating system drivers when not in the pre-boot environment. Select your operating system and version 0. of. HPE ProLiant BL Server Series. Addressed an issue in the HP RESTful API BIOS support that resulted in internal HTTP sessions between BIOS and iLO left open during boot. This can result in the iLO Event Log indicating multiple events for HTTP session logins. Addressed an issue where the Date and Time may be set incorrectly when using the Date and Time option from the BIOS/Platform Configuration (RBSU) when the Daylight Savings Time option is enabled. If your operating system is not listed then HP may not provide driver support for your product with that operating system. This revision of the System ROM includes the latest revision of the Intel microcode which, in combination with operating system updates, provides mitigation for the Speculative Store Bypass (also known as Variant 4) security vulnerability. HP ProLiant DL380 Gen 9 furnishes a high-performance rack solution. Added support for additional Storage Options to BIOS/Platform Configuration (RBSU). Addressed an issue where a system configured for UEFI Boot Mode with an optional PCI Express based USB 3.0 controller installed may not be able to properly load the USB driver under the operating system. HP Enterprise (HPE) supports servers, switches, routers, and tape drives. Addressed a rare issue in which the user was not prompted or was not prompted correctly when exiting the UEFI System Utilities. This revision of the System ROM includes the latest revision of the Intel microcode which, in combination with operating system and hypervisor updates, provides mitigation for the L1 Terminal Fault – OS/SMM (CVE-2018-3620) and L1 Terminal Fault – VMM (CVE-2018-3646) security vulnerabilities.  These vulnerabilities may allow unauthorized disclosure of information residing in the L1 data cache to an attacker with local user access via a side-channel analysis.  These security vulnerabilities are not unique to HPE servers and impact any servers utilizing impacted processors.  Note that this server is NOT vulnerable to L1 Terminal Fault – SGX (CVE-2018-3615), also known as Foreshadow, because this server does NOT support SGX.Â. Disabling this option has been shown to provide performance benefits in a very small subset of configurations including certain Infiniband configurations that require a balanced mix of read and write traffic as well as configurations with multiple x16 devices that utilize the max bandwidth of the PCI-e bus. How does HP use product data collected with this service? The command can be used to download and upload files to/from FTP servers. Reduced boot time when the Dynamic Smart Array B140i RAID is enabled. Mitigations for Variant 1 (Spectre) and Variant 3 (Meltdown) vulnerabilities require only OS updates and are not impacted. HP DL380z Gen9 Virtual Workstation Choose a different product series Warranty status: Unspecified - Check warranty status Manufacturer warranty has expired - See details Covered under Manufacturer warranty Covered under Extended warranty , months remaining month remaining days remaining day remaining - See details This could cause such issues as an inability to boot using the PCIe adapter. Gen9 ISO will have files related to Gen9 and previous versions. Enhanced the System Utilities System Information and the Embedded UEFI Shell sysinfo command to provide additional details for the processor, memory, PCI subsections. Addressed an issue with the fwupdate Embedded UEFI Shell command that may cause the system to become unresponsive during some firmware updates. This issue only impacts systems configured with Intel Xeon 2600 v4 series processors. Drivers may be in development so please check back at a later date or visit the product homepage. This option is only available in UEFI Boot Mode. Addressed an issue that may result in losing the existing UEFI iSCSI Software Initiator boot options if any of the connection parameters (LUN, Remote Port, IP address, login credentials) change. Added thermal support for the latest PCIe expansion cards.Â. ... "The software will not be installed on this system because the required hardware is not present in the system or the software/firmware doesn't apply to this system." Added a new System Utilities BIOS/Platform Configuration (RBSU) IPv6 DHCP Unique Identifier menu that allows the user to select how the UEFI BIOS will use the DHCP Unique Identifier (DUID) for IPv6 PXE Boot. 0. The list of recommended drivers for your product has not changed since the last time you visited this page. Note, the warranty status displayed is subject to the terms of the applicable warranty policy and may be updated periodically. Product description The HPE ProLiant DL380 Gen9 Server delivers the best performance and expandability in the Hewlett Packard Enterprise 2P rackportfolio. Learn more at the Official Hewlett Packard Enterprise Website. If you have the SPP version, please share so that we can share the content report which gives the detailed information of respective SPP. Wait until the installation has finished then click on continue. We will offer drivers and other solutions in this OS first. HP PROLIANT DL380 GEN9 CHIPSET DRIVERS WINDOWS 7 (2020). HP BL460c Gen9 HP DL380 Gen9 HP DL360 Gen9 HP ML350 Gen9 HP DL180 Gen9 HP DL160 Gen9 HP XL230a Gen9; Added support for new HP ProLiant options; Includes VMware driver support; Provides operating system support for Red Hat Enterprise Linux 7 and vSphere 5.5 U2; Contains HP Smart Update Manager v7.1.0 This System ROM revision replaces the 2.50 revision.  An issue was found with the 2.50 revision of the System ROM that may result in a system hang during boot with a messaging indicating “Memory Initialization - complete” with certain memory configurations.  The 2.50 revision of the System ROM has been removed from the HPE Support Site.  It is highly recommended that any customers using the 2.50 revision of the System ROM upgrade to the 2.52 revision or later. Ml10 gen9 tower server, btc solution center. Note that the Integrated Lights-Out (iLO) Firmware had a similar issue. This also addresses an issue in configuring the server UEFI Boot Order using HP OneView and the HP RESTful API. The command can be used to download files from HTTP and FTP servers. HPE ProLiant ML Server Series . Obtain a formatted USB Key media. Javascript is disabled in this browser. Addressed an issue where Processor Core Disable may not function properly, such as disabling the wrong number of cores, when Intel Xeon E5 v4 processors are installed in the system. Addressed an issue where systems configured Intel Xeon E5-2600 v4 processors and 64GB LRDIMMs may experience a Machine Check Exception or NMI event when under heavy stress. Or, view all available drivers for your product below. The boot targets for adapters can be configured using the adapter specific menu in the System Utilities, System Configuration menu, or using management software such as HP Virtual Connect or HP OneView. Addressed an issue where a server configured with a Trusted Platform Module (TPM) and Microsoft Windows 2012 R2 BitLocker might incorrectly prompt the user for a recovery password following a warm reset. Added support to the HP RESTful API to allow the user to configure the UEFI boot order when the system is configured for Legacy Boot Mode. English. Added a new System Utilities BIOS/Platform Configuration (RBSU) NUMA Group Size Optimizations menu that allows the user to select how the platform will report processor grouping to the operating system. This option may be used to work around interaction issues between the system and Microsoft Windows operating systems running in legacy boot mode that can result in the time to be incorrect. Added a new System Utilities BIOS/Platform Configuration (RBSU) Internal SD Card Slot menu located in USB Options that allows the user to disable boot from the embedded SD card. The iSCSI Software Initiator boot support can be enabled on any network card that is in Ethernet mode. Enhanced PCIe resource allocation so that systems configured with multiple PCIe expansion devices may in some cases no longer report a "276 Option Card Configuration Error" during system boot due to not having enough I/O resources to support what is requested by the installed devices. Gen9 +Gen10 may have files related to Gen10 Servers as well.  Additional information is available from Intel’s Security Exploit Newsroom, https://newsroom.intel.com/press-kits/security-exploits-intel-products/. To ensure the integrity of your download, HPE recommends verifying your results with Hp proliant dl380 gen9 server user manual. This revision of the System ROM includes the latest revision of the Intel microcode which provides mitigation for the Rogue Register Read (also known as Variant 3a) security vulnerability. Added support to configure the system to bifurcate PCIe Slot 1 on the DL360 Gen9 or PCIe Slot 2 on the DL380 Gen9. 5. This issue does not affect systems configured in Legacy Boot Mode. For general questions, email us at hpestore.quote-request@hpe.com Added support for an optional Trusted Platform Module (TPM) 2.0. Previous revisions of the System ROM defaulted to scanning all targets. This issue was seen with a Brocade network adapter but could be seen with other adapters. This issue is not unique to HPE servers. HP has scanned your product but currently has no suggestions for driver updates. 2. The user can still control the priority of the boot entries of individual USB devices in the UEFI Boot Order list. Addressed an issue where the system may not properly respond to error events from devices attached to certain PCI Express root ports. HP P89 . Updated help documentation for System Utilities and the UEFI Embedded Shell. Upgrade Requirement:Critical - HPE requires users update to this version immediately. Addressed an issue where the server may become unresponsive when using the PING command from the Embedded UEFI Shell. Addressed various issues where network boot support options might not be applied properly from HP Virtual Connect or HP OneView. Upgrade Requirement:Recommended - HPE recommends users update to this version at their earliest convenience. This release provides updated system ROM images for the latest maintenance releases of HPE ProLiant DL380 Gen9/DL360 Gen9 (P89) Servers, Hewlett Packard Enterprise Software License Agreement, https://support.hpe.com/hpsc/doc/public/display?docId=hpesbhf03912en_us, https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00060570en_us, https://newsroom.intel.com/press-kits/security-exploits-intel-products/, Red Hat Enterprise Linux 6 Server (x86-64), SUSE Linux Enterprise Server 11 (AMD64/EM64T), 5e4c5ee3406b33c3b0e1fe5d1c9920f2d7511375d52ef81988992d4aac1bb050. A Medium level CVE has been assigned to this issue with ID CVE-2018-3640. Some features of the tool may not be available at this time. With previous revisions of the System ROM, the system health LED would not return to GREEN until after a reboot when a failed power supply is replaced. Download the SoftPaq to a directory on a system running Microsoft Windows 2000, Microsoft Windows XP, Microsoft Windows Vista, Microsoft Windows 7, Microsoft Windows 8, Microsoft Windows Server 2003, Microsoft Windows Server 2008, Microsoft Windows Server 2008 R2 or Microsoft Windows Server 2012 and change to that directory. Added support for loading the Embedded UEFI Shell Auto-Startup script from the network in addition to physical/virtual media.   By default, the time is formatted for Coordinated Universal Time (UTC). Addressed an issue where the system may become unresponsive during boot when configured with a HPE Dual microSD device when one of the microSD devices is failed or missing. Note:  This command can be used to view all available drive partitions. This change will impact any scripts written with a dependency on the "SecureBoot" property in the HpBios resource. Dl380 gen9 server. The iSCSI network settings can be configured in the new System Utilities BIOS/Platform Configuration (RBSU) iSCSI Boot Configuration menu, as well as using the HP RESTful API HpiScsiSoftwareInititiator resource type. By default, the system will now only scan for Fibre Channel boot targets that are configured in each adapter. Addressed an issue where the system would not reset configuration settings to defaults when using the Embedded UEFI Shell Sysconfig -d command. Select an operating system and version to see available software for this product. Your session on HP Customer Support has timed out. dear all i have lost SmartStart CD for HP Proliant DL380 G9 , where i can download that software becouse i can;t install windows if not use - 5964269 ... Lost SmartStart for DL380 Gen9 ‎01-30-2017 02:59 AM. This issue only impacted logging when the system performed a warm reset. Addressed an issue where the System Utilities BIOS/Platform Configuration (RBSU) Dynamic Power Savings Mode Response Option when configured for Slow Mode may not efficiently switch processor performance modes resulting in lower than expected performance. Matches. Updated to the latest support modules for Intel Trusted eXecution Technology (TXT) including the Intel Authenticated Code Module (ACM) and Intel Secure Initialization (SINIT) module.   This allows for using the Embedded UEFI Shell as a scriptable deployment environment without the need for physical or virtual media (on a bare metal system). Addressed an issue in accessing the file systems or booting to some RAID0 logical volumes off HP Smart Array controllers. This revision of the System ROM includes the latest revision of the Intel microcode which, in combination with operating system updates, provides mitigation for Variant 2 of the Side Channel Analysis vulnerability, also known as Spectre. Now we want to install them as a Win 2008 R2 server, but we cannot create a NIC teaming. Updated OpenSSL support to version 0.9.8zb to address potential issues that might impact the UEFI Secure Boot support. Here is the List, Click or run in your browser window to install, Let us detect the drivers you need for this HP PC, Our automated tool will simplify the choices you have to make. This issue was seen with a Seagate storage adapter but may impact other devices. This security vulnerability is not unique to HPE servers and impacts any systems utilizing impacted processors. This includes addressing an issue where the system might log a 303/304 Keyboard controller failure error when certain USB KVMs are attached to the system. This BIOS revision allows a wider range of PCIe configurations that request large amounts of I/O to be configured properly. Added support for an FTP command in the Embedded UEFI Shell. End of Life (EOL) means that the HP ProLiant DL380 Gen9 will no longer be sold, marketed, or updated it after the EOL date. Added support for Microsoft Windows 2019. This issue is not unique to HPE servers. Addressed an issue where Wake On LAN does not function if the system was shutdown prior to booting an operating system (such as during the boot process or from the Embedded UEFI Shell). This type of PCI-express card implementation is more common with older PCI-express expansion cards. By choosing to install, I agree to HP’s terms and conditions on data collection. Added support to allow for the ROM Based Setup Utility (RBSU) Power Regulator setting to be set to Static Low or OS Control Mode when the Processor Power and Utilization Support was disabled. This revision of the System ROM includes the latest revision of the UEFI EDK2 support that provides mitigations for a variety of security vulnerabilities.  The following vulnerabilities have been addressed in this System ROM release: CVE-2018-3613 CVE-2017-5731, CVE-2017-5732, CVE-2017-5733, CVE-2017-5734, CVE-2017-5735, CVE-2018-3630, CVE-2018-12178, CVE-2018-12179, CVE-2018-12180, CVE-2018-12181, CVE-2018-12182, CVE-2018-12183, CVE-2018-12201, CVE-2018-12202, CVE-2018-12203, CVE-2018-12204 and CVE-2018-12205. For additional information please refer to the security bulletin at https://support.hpe.com/hpsc/doc/public/display?docId=hpesbhf03912en_us. 10° to 35°C (50° to 95°F) at sea level with an altitude derating of 1.0°C per every 305 m (1.8°F per every 1000 ft) above sea level to a maximum of 3050 m (10,000 ft), no direct sustained sunlight. This change only prevents the display of the erroneous message and does not impact USB functionality. Addressed an issue where the HPE RESTful settings for Software Initiator iSCSI may not be available in the resource registry. In rare cases, this could cause the system to not optimally switch processor power states. Systems with microprocessors utilizing speculative execution and speculative execution of memory reads before the addresses of all prior memory writes are known may allow unauthorized disclosure of information to an attacker with local user access via a side-channel analysis. Addressed an issue where the System Utilities BIOS/Platform Configuration (RBSU) option for Embedded UEFI Shell Auto Startup Script Network Location does not accept an NSH file name containing upper case characters. Addressed an issue where the Administrator Password and Power-On Password were incorrectly allowed to be entered with a length of 32 characters with previous revisions of the System ROM. Addressed an issue where messages displayed during the early boot process would not be displayed properly when viewed over BIOS Serial Console. Addressed an issue where the system may fail to boot from existing UEFI iSCSI Software Initiator boot options if the user changed the iSCSI Target IP address. 3. Detection was successful but you don’t need any new drivers at this time, Visit the product home page for more support options. Addressed an issue where the Automatic Server Recovery (ASR) setting may not be configured properly through the HP RESTful API. Examples: "LaserJet Pro P1102 paper jam", "EliteBook 840 G3 bios update", HP Support Solutions Framework - Windows Service, localhost Web server, and Software, Remove "HP Support Solutions Framework" through Add/Remove programs on PC, Operating System - Windows 7, Windows 8, Windows 8.1, Windows 10, Browser - Google Chrome 10+, Internet Explorer (IE)10.0+, and Firefox 3.6.x, 12.0+. Updated the HP RESTful API HPE BIOS Attribute Registry resources to match the latest BIOS/Platform Configuration options. Detected operating system: This issue does not impact systems configured for UEFI Boot Mode. Added support for Memory Mirroring Mode.   Added support for Trusted Platform Module (TPM) 2.0 Firmware flash updates. Addressed an issue where optical drives were not properly reported in the server One Time Boot Menu when the HP Smart Array B140i Smart Array controller is enabled. Skip the confusion of sorting through all of our drivers and let us detect only the ones you need. Try our automated HP Audio check! ESXi 6.5 U2 Apr 2019 – Supports Gen9 Servers and forward ; ESXi 6.5 U1 Feb 2018 – Supports Gen9 Servers and forward; ESXi 6.5 U3 Dec 2019 - Last Pre-Gen9 custom image; ESXi 6.5 U2 Sept 2018 – Last Pre-Gen9 custom image; ESXi 6.5 U1 Nov 2017 – Last Pre-Gen9 custom image; ESXi 6.5 Oct 26, 2017 – Supports Gen9 Servers and forward This issue does not affect any other processor models. Technical data is gathered for the products supported by this tool and is used to identify products, provide relevant solutions and automatically update this tool, to improve our products, solutions, services, and your experience as our customer. Audio or sound issues? Due to the severity of the potential issues that may occur when using these microcodes addressing Variant 2, Intel now recommends that customers discontinue their use.  Additional information is available from Intel’s Security Exploit Newsroom, https://newsroom.intel.com/press-kits/security-exploits-intel-products/.  HPE is in alignment with Intel in our recommendation that customers discontinue use of System ROMs including impacted microcodes and revert to earlier System ROM versions. This issue is NOT unique to HP servers. The Virtual Agent is currently unavailable. This revision of the System ROM includes the latest revision of the Intel microcode which addresses an issue where the system could experience an unexpected reset or shutdown with no errors logged to the Integrated Management Log (IML). The user can now optionally select to use the DUID-LLT as the unique identifier for PXE Boot. Added support to Standard Format Output (SFO) to the SysConfig command in the Embedded UEFI Shell. Addressed an issue where the Legacy Boot Order menu in the System Utilities BIOS/Platform Configuration (RBSU) might have incorrect port numbers when the server is configured in Legacy Boot Mode. Booting Windows or Linux OS installation media is currently not supported. This revision of the System ROM includes the latest revision of the Intel microcode which addresses an issue where the system could experience an unexpected reset or shutdown with no errors logged to the Integrated Management Log (IML). Locate the file in your browser window, and double-click to begin installing. From that drive and directory, execute the downloaded SoftPaq file: Simply double click on the SPxxxxx.exe file and follow the installation wizard to complete the SoftPaq installation process. Proceso de actualización de firmare de los servidores, en este caso se ha realizado el update de versión de sistema operativo This System ROM revision should be considered the minimum revision required for use with 64 GB LRDIMMs in systems with any memory channels containing 3 DIMMs. Addressed an issue where certain optional PCIe video adapters would fail to work properly when using a Linux operating system. What is HP ProLiant DL380 Gen9 End of Life (EOL)? Addressed an issue where the server would become unresponsive during boot with DIMM configurations that include both when configured with 16GB and 32GB LRDIMMs. HP ProLiant DL380 Gen 9 furnishes a high-performance rack solution. This issue is not unique to HPE servers. This command can be used to configure the server through the HP RESTful services. In this case, the user must set Switch 5 to the ON position to disable these passwords. Pci slots slots, hewlett packard enterprise software. For some applications which cannot optimally handle high logical processor counts that are optimally divided into smaller groups, it might be necessary to change the default setting to get optimal performance. Addressed an issue where a USB key was still bootable when the USB Boot Functionality was disabled from System Utilities BIOS/Platform Configuration (RBSU). This includes the latest list of revoked certificates. This page requires Javascript. DRIVERS HP PROLIANT DL380 GEN9 ILO FOR WINDOWS. Learn more​. Search. Addressed an issue with the sysconfig Embedded UEFI Shell command that may cause the system to become unresponsive when using "sysconfig -d get userdefaults all" when the user defaults have not been configured. Added support for a Generic USB Boot entry in the UEFI Boot Order list. Please try again later. Addressed an issue where the server may display a Red Screen error and become unresponsive during boot when more than 256 hard drives are attached to a storage controller. These cookies are necessary for the website to function and cannot be switched off in our systems. Â, End User License Agreements:OpenSSL License Agreement, Version 0.9.8UEFI EDK2 License. Addressed an issue where the server may assign incorrect ACPI NUMA proximity allocations for servers configured with two or more processors and with memory only attached to a single processor socket potentially leading to non-optimal performance. Addressed an issue in which an Interphase audio streaming PCI-express expansion card may not achieve optimal performance resulting in dropped packets when streaming data. Updated branding during the boot process and in the pre-boot System Utilities from HP to Hewlett Packard Enterprise. HP supports printers, pc's, tablets and calculators . Addressed an issue where a system could become unresponsive when booting to Linux Operating when serial output was enabled from the operating system and the iLO Virtual Serial Port was the only enabled UART. Note: This tool applies to Microsoft Windows PC's only. Reliability, serviceability and near continuous availability, backed by a comprehensive warranty, make it ideal for any environment. The change also removes the System Utilities BIOS/Platform Configuration (RBSU) option for ACPI RTC Support. The Administrator Password and Power-On Password must then be re-entered into the system with a maximum length of 31 characters. Added a Server Security BIOS/Platform Configuration (RBSU) option to Enable or Disable "Processor AES-NI Support". Solved: hello, where to find the latest bios for dl380 Gen9 server ? Sign up for driver, support & security alerts. Why Should we Patch ROM Firmware? Reliability, serviceability and near continuous availability, backed by a compr ehensive warranty, make it ideal for any When Network VLAN Configuration is enabled, the server would always attempt to boot both iPV4 and iPV6 regardless of the PXE Boot Order Policy setting. Added pre-boot OHCI USB support. Addressed an issue where a server configured for UEFI boot mode may become unresponsive during boot when configured with an optional graphics controller that does not support UEFI boot mode.